EVO™ 600 & EVO™ 6000
EVO™ 600 & EVO™ 6000
EVO™ 600 & EVO™ 6000 provide highly accurate inventory management and full-featured compliance monitoring for any size fuel system. The EVO™ Series offers a robust platform that transcends conventional fuel management by automating fuel system operations, enhancing C-store performance, and providing remote access to critical data so operators can run their business as efficiently as possible.
With right-size options for any operation, advanced features, intuitive design, and superior scalability, the EVO™ Series is engineered to evolve with your business.
Achieve optimal flow rates, maximize uptime,
and minimize maintenance truck rolls with EVO™ Series.
Get highly accurate, real-time fuel inventory intelligence
Make informed, data-driven inventory / delivery decisions
Automate compliance monitoring, testing, and reporting
Navigate effortlessly with user-friendly touchscreen
Ensure uptime with advanced pump monitoring and control
Minimize leaks with continuous Electronic Line Leak Detection
Connect to your data anywhere, anytime via PRO® Connect
Reduce downtime with automatic firmware upgrades
Optimize throughput via real-time flow rate ana
Deploy fast with hassle-free software setup tools
Stay secure with user roles, tracking, & multifactor log-in
Secure data encryption with the latest TLS/SSL protocols

The EVO™ Series features capabilities that empower every user type to make informed, data-driven inventory management decisions while keeping sites in compliance and operating at peak performance.

TURBINE PUMP
INTERFACE™
Enhanced remote pump monitoring and control including pump-in-water automation, clogged intake escalation, tank leveling, tank priority, and more.

LEAK
DETECTION
Electronic Line Leak Detection (ELLD) continuously monitors pipework to detect leaks and provide hourly, monthly, and annual precision line leak detection compliance testing requirements.

TANK
MONITORING
Make informed, data-driven inventory management decisions with highly accurate tank level monitoring, tank autocalibration, and inventory reconciliation.

CONTAINMENT
MONITORING
EVO™ provides containment monitoring to detect water or fuel leaks in sumps and interstitial spaces, ensuring early detection and compliance with environmental regulations.

DEF/ADBLUE®
MONITORING
Automate the recirculation of DEF as a means to prevent freezing and monitor line temperatures, recirculation status, and inventory levels.

FLOW RATE
MONITORING
Detect and react to potential slow flow issues with automated daily reporting and alarms,
helping to improve flow rates and dispenser throughput.

CORROSION
CONTROL™
Fully automate the removal of corrosion-causing water from tanks, monitor for corrosive environments, and streamline maintenance activities.

SECONDARY
CONTAINMENT
Monitor for and detect leaks in double-wall piping, tanks, and sumps to ensure early
warning of breaches and support environmental compliance.

The EVO™ Series offers a robust set of features designed to enhance operational efficiency, ensure compliance, and provide actionable insights for fuel and C-store management.

ONE TOUCH
BUTTONS
Automate and carry out anything from complex, multi-function processes to simple daily delivery report generation – all with the touch of a single button.

COMPLIANCE
MONITORING
Full-featured compliance monitoring with monthly and annual tank testing, containment testing, and line testing – even for busy sites with minimal downtime.

CUSTOM
APPS
Logic Conditions lets users create custom applications to do things like automate compliance testing, reporting, and additional C-store operations activities.

AUTO FIRMWARE
UPGRADES
EVO™ can perform automatic firmware version upgrades, ensuring the system stays current with the latest features and security enhancements without a service truck roll.

THEFT
DETECTION
Monitor for product loss during any idle fueling periods. If there is a product loss larger than a user-set threshold during idle periods, EVO™ will send an alert of a potential threat occurrence.

ADVANCED
REPORTING
Easily generate detailed reports (from inventory and deliveries to leak tests and alarm history) scheduled automatically and delivered via email for streamlined reporting.

ALARMS &
EVENTS
Operators can easily manage system events with instant email or SMS alerts, a detailed event log, and remote access to quickly acknowledge or resolve issues.

AUTO SYSTEM
BACKUPS
If the site unexpectedly goes down, there's no need to reprogram it from scratch with regularly emailed system backup files that contain historical regulatory information and configuration settings.

EVO™ Series helps operators maintain compliance, protect their sites from leaks, and stay connected to vital inventory data anytime, anywhere.

Inventory Management
Track and manage fuel inventory levels, optimize fuel supply, and prevent runouts with inventory automation and customizable delivery notifications.

Compliance Monitoring
Monitor and automate compliance-related activities, simplify regulatory reporting requirements, and ensure optimal fuel system performance.

Leak Detection
Proactively identify and address any potential issues, ensuring the safety and integrity of fuel storage, pipework, and the distribution processes. (Optional)

EVO™ Series features intuitive controls and clear visual cues, allowing users to easily access all functionalities without extensive training. Whether viewing line status, setting up alerts, or accessing testing information, EVO™ simplifies complex tasks for an easy user experience.

One Touch Buttons
The home screen can be customized with up to six One Touch Buttons. These buttons simplify routine tasks for on-site staff and help automate fuel system corrective actions in the event of an alarm.

Quick Jump Menu
Navigate quickly through applications with ease. This time-saving menu makes the interface’s structure extremely shallow, simple to navigate, and reduces the amount of steps it takes to accomplish tasks.

Icon-Based Design
Designed with a smartphone-like interface, EVO™ ONE features colorful apps, status indicators, and intuitive navigation, making it easy for new users to operate with minimal training.

Custom Colors
Customizable fuel grade colors make it easy for users to identify fuel grade types, check tank water levels, and identify any potential issues at a glance.

The PRO® Connect Web Browser Interface allows operators to securely and remotely connect to EVO™ from any web enabled device. Automatic scaling provides access to site information whether using a PC, tablet, or smart phone.

Remote Access
Displays data in a user-defined schedule, or in real-time
Offers immediate notification of alarms for timely response
Centralized monitoring of all compliance information
Configure custom applications and system automation
Analyze and respond to system events and alarms

Monitoring Capabilities
Get remote access to vital site data including tank status, sensor status, pump status, delivery information, active events, alarm history, event history, and more.
- Tank Status
- Sensor Status
- Line Status
- SCM Status
- Pump Status
- Water Separator Status
- Compliance Status
- Conditions
- DEF Recirculation Status
- Shift Status
- Events

Inventory Forecasting
Remotely monitor tank levels, view delivery information, and check the predicted days of remaining inventory to precisely schedule deliveries and avoid costly run-outs.

Simplified Reporting
A wide variety of reports including inventory, alarm history, delivery history, sensor status, and regulatory compliance can be customscheduled, displayed, printed, or emailed at specific times.

The EVO™ Series helps keep sites in compliance while providing marketers with the highest level protection from the security threats facing our industry.

Inventory & Leak Detection Probes
Digital inventory and leak detection probes provide accurate tank level monitoring and reporting with optional leak detection capabilities. These probes employ digital communications and magnetostrictive position measurement technology for highly accurate tank readings. Probes are paired with float kits for advanced inventory monitoring and control.
Standard Gas & Diesel Floats
Measure fuel and water levels in tanks using paired product and water floats.
Phase Separation Floats
Detect both water and ethanol phase separation to help prevent fuel quality issues.
Diesel Low Level Water Float
Detects water levels as low as ¼" for early warning inside diesel tanks.
Chemical Float
Stainless steel float designed for monitoring non-hydrocarbon liquids like DEF.
LEARN MORE ABOUT PROBES

Leak Detection Sensors
No matter what the application is, there’s an EVO™ Series containment monitoring solution to fit your needs. From dispenser sumps and turbine sumps, to tank interstitial spaces and specialty applications, theres an EVO™ Series compatible sensor option to meet your requirements.
Liquid Sensors
Detect the presence of liquid in containment areas to indicate potential leaks.
Discriminating Sensors
Identify and differentiate between fuel and water to enable specific leak response.
Magnetostrictive Sensors
Identify and differentiate between fuel and water to enable specific leak response.
Interstitial Sensors
Monitor the space between double walls to alert of leaks in tanks or piping systems.
LEARN MORE ABOUT SENSORS

Module-Based Design
The EVO™ 600 and EVO™ 6000 feature a module-based design. This offers the flexibility to customize probe, sensor, and input configurations to meet the specific needs of any site while ensuring seamless scalability in the future.
Sensors, probes, and additional system devices are wired through the modules using either two-wire or three-wire configurations. The modules serve as centralized hubs, routing power to the devices and device data to the EVO™ Series console for centralized monitoring and control.
Universal Device Protocol (UDP) Module
The versatile UDP module provides universal compatibility with most common probes and sensors. With 12 inputs, the UDP module is capable of supporting more inputs and system flexibility than any other module.
LEARN MORE ABOUT MODULES

Multiplexing Sensor Hub™
The Multiplexing Sensor Hub™ (MSH) allows station owners to add additional sensors to existing sites without having to break concrete to run new conduit and wires. The MSH utilizes existing cabling to power and connect up to six total devices to an EVO™ Series console.
Expansion Consoles
In addition to the EVO™ 600 & 6000’s factory-installed modules, both are also compatible with Expansion Consoles to add more modules and additional inputs for larger operations or future upgrades. Expansion consoles include a Power Supply module and space for additional modules, connecting to the primary EVO™ Series console via the BUS extension port.
LEARN MORE ABOUT EXPANSION

Remote Audible & Visual Alarms
Remote Audible & Visible Alarms enhance safety and compliance by providing clear, immediate notifications of critical conditions at fuel sites, ensuring swift operator response. Integrates with EVO™ Series consoles to deliver standard-intensity alerts for tank overfill or general-purpose alarm conditions.
Remote Alarm Acknowledge Unit
Complements remote alarm systems by enabling operators to manage and silence alerts from a distance.
High Intensity Alarm
Provides powerful audible and visible alerts to ensure critical conditions are noticed even in noisy or remote settings.
LEARN MORE ABOUT ALARMS

The EVO™ Series offers additional advanced features and capabilites to manage your entire system as efficiently as possible.

Electronic Line Leak Detection
EVO™ Series Electronic Line Leak Detection (ELLD) is designed to provide early detection of leaks in pressurized fuel lines. The system features automatic submersible pump shutdown in the event of a leak, minimizing the risks of costly spills and environmental cleanup. This pressure-based system utilizes learned line characteristics to monitor for changes in pressure to declare the line as tight or determine if a leak is present.
LEARN MOREEVO™ leverages AUTO-LEARN® technology to automatically program the unique pressure characteristics of each pipework system. This ensures precise, customized leak detection, reducing the risk of false alarms and enhancing overall system accuracy.
With Statistical Line Leak Detection (SLLD), EVO™ allows sites with constant fuel flow to perform 0.2 gph leak testing even during peak operation. This is ideal for busy fuel stations where quiet periods are rare, ensuring continuous compliance without disrupting operations.

Turbine Pump Interface™
Turbine Pump Interface™ (TPI) is a powerful tool that creates a network between intelligent pump controllers and EVO™ Series fuel management system consoles. Through TPI, the EVO™ has access to the submersible pumping system status and the capability to react with intelligence that pump controllers alone cannot. The devices share data to provide enhanced system capabilities.
LEARN MOREDetect and automatically react to offline systems for faster reset and avoided downtime.
Provide remote troubleshooting, preventing maintenance calls and trip charges.
Prevent fuel runouts, dry runs, tank overfills, and water being pumped into a vehicle.

Corrosion Control™ System Integration
Monthly inspections, compliance testing, dispenser filter changes, etc. The list of maintenance initiatives marketers must keep track of goes on and on. With the influx of corrosion-related maintenance issues on the rise, the EVO™ Series can fully automate corrosion prevention, mitigation, and monitoring.
LEARN MOREAutomate the removal of corrosion-causing water from tank bottoms.
Detects corrosive tank ullage environments for prompt response.
Monitors the remaining life of Desiccant Packs to streamline maintenance.
Multiplexing Sensor Hub™ can add equipment qithout breaking concrete.

Inventory Reconciliation
The EVO™ Series offers an advanced, automated approach to inventory reconciliation, providing a crucial layer of environmental protection for fuel stations. This feature ensures that operators can detect potential leaks quickly and accurately by analyzing tank volume, deliveries, and dispenser sales data.
Collects dispenser, delivery, and tank data for full fuel movement insight.
Compares expected vs. actual volumes to flag potential discrepencies.
Alerts when unaccounted tank volume changes suggest leaks or theft.
Generate reports with full data traceability for audits and reviews.

Sentinel Mode: Fuel Theft Detection
Sentinel Mode enhances security by continuously monitoring product levels during both site closure and idle fueling periods, alerting operators to potential theft when losses exceed a user-defined threshold.
During site closure EVO™ can monitor for any product loss larger than a user-set threshold and alert of potential theft occurrences.
For sites that operate 24 hours a day, EVO™ can monitor product levels when the tank’s associated pump(s) have no active hook signals; and if there is a product loss larger than a user-set threshold during idle fueling, alert of a potential theft occurrence.

Remote Control Solution with OVERSITE™
Supercharge system intelligence by connecting an EVO™ Series console to the Remote Control Solution (RCS). With EVO™, the RCS becomes smarter and more responsive with automated event response triggers based on real-time site data with no manual input required.
LEARN MOREWith OVERSITE™ remote monitoring and power cycling capabilities, C-Store operators can remotely reset fuel dispensers, site controllers, submersible pumps, and more, significantly reducing the need for costly on-site maintenance trips and eliminating the expenses associated with extended downtime.
The RCS also provides advanced device power status monitoring, remote E-Stop engagement, and remote power resetting capabilities for fuel system and C-store critical assets.

Custom Apps with Logic Conditions
Transform your system management EVO™ Series Logic Control Conditions. This cutting-edge feature empowers operators to create tailored applications, automate critical processes, and take control like never before. From compliance to operational efficiency, Logic Conditions unlocks endless possibilities for your fueling system.
Schedule and execute static tank tests and automatically print or email results.
Shut down systems when high water levels or fuel leaks are detected.
Schedule inventory and delivery reports at shift ends or after deliveries.
Control station lighting with timers, turning lights on at dusk and off at dawn.
Set up alerts for critical events and trigger actions sending email notifications.
Use counters to monitor delivery frequency or equipment cycles.

DEF Recirculation Monitoring & Control
Because AdBlue®/Diesel Exhaust Fluid (DEF) will freeze at around 12° F (-11° C ), no DEF system is complete without a means to prevent it from freezing in the lines and causing damage. The EVO™ Series DEF Recirculation application allows users to automate the recirculation of DEF as a means to prevent freezing while also providing DEF inventory management and line monitoring capabilities.
LEARN MORESelect user-defined temperatures at which recirculation is both triggered and shutoff, allowing EVO™ to automate operation and navigate fluctuating environmental temperatures in an energy efficient manner.
Get a quick snapshot of key system performance indicators, line temperatures, recirculation status, and inventory levels.

Flow Rate Monitoring
Improve dispenser throughput and maintain fast flow rates with the ability to detect and react to potential slow flow issues before they impact business. Flow Rate Monitoring calculates flow rates for each fueling point and provides a notification if transactions dip below a user-defined set point.
LEARN MOREMonitor for and ensure fast and consistent dispenser throughput with daily reports and alarm notifications regarding flow rate performance. Improve dispenser throughput by detecting slow flow issues and addressing them before they impact sales.
Sales and dispensing duration data are automatically reconciled to help you better understand the flow performance of every fueling point. Help reduce customer wait times at the dispenser and increase the likelihood of in-store sales.

Secondary Containment Monitoring
The Secondary Containment Monitoring (SCM) system is designed to detect leaks in double-wall piping, tanks, and sumps. The system utilizes the siphon / vacuum port of a submersible turbine pump to draw a vacuum on these interstitial spaces. The vacuum levels are then continuously monitored by an EVO™ Series console to detect any potential leaks in these double-wall containments.
LEARN MOREThe SCCM collects information on all interstitial spaces and gathers system status, replenish rate, alarm, and diagnostic information.
The EVO™ Series console will alarm when a vacuum cannot be maintained or when liquid is detected in a secondary space. Optional positive submersible pump shutdown can be enabled upon alarm.

Capabilities
Inventory Monitoring
Provides real-time tracking of fuel levels within storage tanks. This enables station owners to manage inventory effectively, reducing the risk of runouts or overfilling.
Inventory Reconciliation
Compares dispensed fuel amounts with actual inventory levels to identify discrepancies. This helps detect potential leaks or theft, ensuring product accountability and environmental compliance.
Tank Autocalibration
Automatically adjusts tank capacity measurements to reflect actual conditions by referencing sales data. This enhances measurement accuracy, leading to more precise inventory management and compliance reporting.
Static Tank Testing
Conducts scheduled, non-intrusive tests to verify tank integrity. Station owners benefit by ensuring regulatory compliance and preventing environmental contamination.
Statistical Continuous Automatic Leak Detection (SCALD®)
SCALD® continuously analyzes data to detect tank leaks without requiring shutdowns or interrupting fueling. Ideal for 24/7 sites with minimal quiet periods, it ensures compliance without disrupting operations.
Containment Compliance Monitoring
Monitors containment sumps and tank interstitial for leaks or breaches. This ensures early detection of containment failures, protecting the environment and aiding in regulatory compliance.
Programmable Logic Conditions (Custom Applications)
Enables customization of system responses based on specific site conditions. This flexibility allows station owners to automate processes, enhancing operational efficiency.
DEF/AdBlue® Recirculation
Automates Diesel Exhaust Fluid (DEF) recirculation with user-set temperature thresholds to prevent freezing, while also monitoring line status for leaks.
Electronic Line Leak Detection (ELLD)
Utilizes electronic sensors mounted in the submersible pump to detect leaks in fuel lines. Early detection prevents product loss and environmental hazards, ensuring system integrity.
AUTO-LEARN® ELLD Line Learning
Automatically learns the characteristics of fuel lines to enhance leak detection accuracy. This ensures precise, customized leak detection, reducing the risk of false alarms and enhancing overall system accuracy.
Statistical Line Leak Detection (SLLD)
Analyzes pressure and flow data over time to identify leaks. This allows sites with constant fuel flow to perform 0.2 gph leak testing, even during peak operation, which ensures continuous compliance without disrupting operations.
Secondary Containment Monitoring (SCM)
Detects leaks in double-wall piping and tank/containment interstitials utilizing the siphon/vacuum port of a submersible pump to draw a
vacuum and monitor the pressure of these interstitial spaces.
Remote Access via PRO® Connect
Provides off-site access to system data and controls through a secure web interface. Station owners can monitor and manage their sites remotely, improving response times and operational oversight.
Turbine Pump Interface™ (TPI)
Creates a network between intelligent pump controllers and EVO™ allowing real-time data sharing and intelligent system responses. This enables remote troubleshooting and reduced downtime.
Fueling Point Flow Rate Monitoring
Reconciles sales and dispensing data to calculate flow rates at each fueling point, providing alarm notifications if performance
drops below a user-defined threshold. Ensures consistent flow rates and proactive maintenance.
Corrosion Control™ System Automation
Fully automates the removal of corrosion-causing water from tanks and provides proactive automated detection and notification of a corrosive environment in the tank ullage space.
Components

- There can only be three types of one module, except for the UDP Module, which allows for up to six in an EVO™ or Expansion Console.
- If you require more than three types of one module (other than the UDP Module) in an EVO™ or Expansion Console, please contact your FFS sales representative to review your needs.
- The intrinsically safe barrier must be installed in the third slot or greater. (The third slot after the power supply module.)
1. Cover
2. LCD Touch Screen
3. LED Indicators
4. Printer
5. Mounting Tabs
6. Cooling Vents
7. Module Slots
8. Communication Ports
9. Annunciator (audible alarm)
10. Ethernet Port 1
11. Ethernet Port 2
12. USB Port (Type-A)
13. USB Port (Mini-B)
14. RS-232 Comm Port 1
15. WiFi
16. Bus Extension
17. RS-232 Comm Port 2
18. RS-485 / TPI
19. Controller Module
20. Power Supply Module
21. AC Input Module (TS-ACI)
22. 10 Amp Relay Module (TS-10ARLY)
23. I/O Module (TS-IO)
24. 4-20mA Module EXP (TS-420EXP)
25. Relay Module (TS-RLY)
26.Blank
27.Intrinsically Safe Barrier
28.Probe Module (TS-PRB)
29.4-20mA Module (TS-420IB)
30.2-Wire Sensor Module (TS-2WSNS)
31.3-Wire Sensor Module (TS-3WSNS)
32.RS-485 Module (FMP-485IS)
33.UDP Module (FMP-UDP9)
Specifications
Maximum tanks monitored (stand-alone) | 48 (EVO™ 600) / 72 (EVO™ 6000) |
Maximum tanks monitored, with accessories | 132* (EVO™ 600) / 168* (EVO™ 6000) |
Maximum sensor input capacity (stand-alone) | 48 (EVO™ 600) / 108 (EVO™ 6000) |
Maximum sensor input capacity, with accessories | 180* (EVO™ 600) / 244* (EVO™ 6000) |
Maximum total inputs (stand-alone) | 72 (EVO™ 600) / 132 (EVO™ 6000) |
Maximum total inputs, with accessories |
276* (EVO™ 600) / 336* (EVO™ 6000) |
Maximum AC input channels (stand-alone) |
36 (EVO™ 600) / 36 (EVO™ 6000) |
Maximum AC input channels, with accessories | 72* (EVO™ 600) / 72* (EVO™ 6000) |
Maximum relay output channels (stand-alone) | 26 (EVO™ 600) / 26 (EVO™ 6000) |
Maximum relay output channels, with accessories | 50* (EVO™ 600) / 50* (EVO™ 6000) |
Dry contact input channels | 2 |
Connectivity | Ethernet (qty 2). RS-232, RS-485, standard USB, Mini-B USB |
Display type | 7" (17.78 cm) color LCD touch screen |
Printer type | Thermal (also network or USB) |
Alarm | Internal audible alarm |
LEDs | Alarm, warning, and power |
Applicable liquids | Petroleum, chemicals, and waste |
Level units | Inches, centimeters, and millimeters |
Volume units | Gallons or liters (mass with density option) |
Power requirements | 110 to 240 VAC, 50/60 Hz, 1.5 Amps |
Operating temperature | 32° to 104° F (0° to 40° C) |
Humidity | 0-90% non-condensing |
EVO™ 600 | H: 11.75"(300 mm), W: 10¼"(260 mm), D: 9"(229 mm) |
EVO™ 6000 | H: 11.75"(300 mm), W: 16½"(419 mm), D: 9"(229 mm) |
Alarm set points | High/low product, water, and temperature |
Technical Advantages | Inventory reconciliation/tank autocalibration/flow rate monitoring |
Measurements | Density, mass, and phase separation measurement |
Notifications | Email and SMS |
Programming | Back-up generator monitoring/conditions |
Advanced Logic Control | DEF/AdBlue® recirculation system |
Support | MODBUS™ |
Approvals | UL, cUL, ATEX, IECEx, GSA IT Security |
Certifications |
|
*Requires use of FMP-EXPC Expansion Modules and/or FMP-MSH Multiplexing Sensor Hubs.
Ordering Guide
EVO™ model, software and hardware options can be listed separately or combined when ordering. Systems shipped from the factory will list the combined part number. Complete part numbers have a specific order and are created using the following guidelines:
EVOX DPWI / TRFLGC
- EVOX = Base Model Options
- EVO600 = EVO™ 600 base ATG
- EVO6000 = EVO™ 6000 base ATG
- DPWI = Hardware Options (choose all that apply)*
- D = Display
- P = Printer
- W = Wifi
- I = Dispenser interface module
- TRFLGSC = Software Options (choose all that apply)
- T = SCALD 24-hour tank testing
- R or F
- R = Reconciliation/Autocalibration
- F = Reconciliation/Autocalibration with Flow Rate Monitoring
- L or G
- L = Line leak detection
- G = Generator Line Leak Detection
- S = Secondary Containment Monitoring
- C = DEF/AdBlue® recirculation, enhanced logic conditions including value, counter, value compare, and latch
Example: EVO600DPWI/TRL = EVO™ 600 base model with display, printer, WiFi, Dispenser Interface Module, SCALD®, Reconciliation/Autocalibration, and line leak detection.
EVO™ 600 and EVO™ 6000 Interface Modules
The EVO™ 600 and EVO™ 6000 come standard with a power supply module and a controller module. Additional interface modules can be installed. Interface modules ordered with an EVO™ will be installed at the factory. If you would like them to not be installed, please order the spare/replacement version of the module. The following guidelines must be followed:
- EVO™ 600: Six total modules can be installed with a maximum of four intrinsically safe modules and a maximum of three of any one kind of module, except for the UDP Module, which allows for a maximum of four modules.
- EVO™ 6000: Eleven total modules can be installed with a maximum of nine intrinsically safe modules and a maximum of three of any one kind of module, except for the UDP Module, which allows for a maximum of six modules.
Note: Do not include the Power Supply and Controller Modules when calculating total modules allowed.
Maximum UDP Modules Allowed to Run Concurrently with Probe Modules in a Single EVO™ Console or Expansion Console
The UDP Module is intended to replace the Probe Module for all new system orders. If you are planning to add UDP Modules to an existing EVO™ 600/6000 with Probe Modules, please adhere to the following table:
Existing Probe Modules | Allowable UDP Modules |
0 | 6 |
1 | 4 |
2 | 2 |
3 | 0 |
Pre-Installed Intrinsically Safe Modules
Model Number | Description |
---|---|
FMP-485IS | Pre-installed RS-485 Module | 4 MSH inputs (allows for 24 total inputs) | Compatible with FMP-MSH multiplexing sensor hubs (EVO™ 600/6000 only) |
FMP-UDP9 | Pre-Installed UDP Module | 12 inputs | Compatible with FMP-LL3-XXX and FMP-LL3-XXX-I probes, FMP-UHS and FMP-ULS sensors, and FMP-XXX-U sensors (EVO™ 600/6000 only) |
TS-2WSNS | Pre-Installed 2-Wire Sensor Module | 12 inputs | Compatible with FMP-HFS2, FMP-UHS, FMP-ULS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors |
TS-3WSNS | Pre-Installed 3-Wire Sensor Module | 8 inputs | Compatible with FMP-DDS*, FMP-DIS*, FMP-DTS*, FMP-EIS*, FMP-HIS*, FMP-HIS-XL*, FMP-UHS*, FMP-ULS*, TSP-DVS, TSP-HLS-XX, and TSP-HLS-XX/SS sensors |
TS-PRB | Pre-Installed Probe Module | 12 inputs | Compatible with TSP-LL2-XXX, TSP-LL2-XXX-I, FMP-LL3-XXX, and FMP-LL3-XXX-I probes; TSP-DMS-XX and FMP-XXX-U sensors; and VFM vapor flow meters |
TS-420IB | Pre-Installed 4-20 mA Module | 8 inputs | Intrinsically Safe | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors |
- -U sensors are not supported on the 2-wire or 3-wire sensor module.
Pre-Installed Non-Intrinsically Safe Modules
Model Number | Description |
---|---|
TS-10ARLY | Pre-Installed 10 Amp Relay Module | 6 outputs | 10 Amp | Compatible with high power dispenser shutdown control functions |
TS-420EXP | Pre-Installed 4-20 mA Module | 8 inputs | Explosion-Proof | Compatible with TS-LSU500/X transducers and FMP-TEM, TS-VPS, and TS-SCCM sensors |
TS-ACI | Pre-Installed AC Input Module | 12 inputs | Compatible with dispenser hook signal monitoring functions |
TS-IO | Pre-Installed Input Output Module | 4 4-20 mA outputs | 8 3-240 VAC/DC inputs | Compatible with remote monitoring control and building monitoring system interfacing functions |
TS-RLY | Pre-Installed Relay Module | 8 outputs | 2 Amp | Compatible with TS-LSU500/X transducers, TPI, and TS-SCCM control functions |
- TS-RLY Module is not required for STP control when utilizing turbine pump interface (TPI) communications. The TS-420EXP module requires Controller Module software version 9.5 or greater Do not include Power Supply and Controller Module when calculating total modules allowed.
Expansion Consoles
The EVO-EXPC2 must follow the same guidelines as the EVO™ 600, and the EVO-EXPC must follow the same guidelines as the EVO™ 6000.
Model Number | Description |
---|---|
EVO-EXPC | Secondary console to add eleven additional plug-in modules to the primary TS-550, TS-5000, EVO™ 550, EVO™ 5000, EVO™ 600, EVO™ 6000 ATG, comes without a display or printer |
EVO-EXPC2 | Secondary console to add six additional plug-in modules to the primary TS-550, TS-5000, EVO™ 550, EVO™ 5000, EVO™ 600, EVO™ 6000, comes without a display or printer |
EVO™ 600 & EVO™ 6000 Hardware & Software Field Upgrades
The following software and hardware options can be added to customize your EVO™ once it's been installed in the field.
Hardware Field Upgrades
Model Number | Description |
---|---|
EVO-DISPREP | Display upgrade for an EVO™ 600/6000, EVO™ 550/5000 with existing Interface Board REV 4 or lower |
EVO-TMPTR | Thermal internal printer assembly upgrade for an existing EVO™ 600/6000, EVO™ 550/5000, comes with one roll of printer paper |
FMP-WIFI | WiFi upgrade for an existing EVO™ 200/400, EVO™ 600/6000, includes 4.5" antenna |
EVO-DIMIB | Internal Dispenser Interface Module upgrade for an existing EVO™ 600/ 6000, dispenser interface cable must be ordered separately |
EVO-LCD | Display upgrade for an EVO™ 600/6000 with existing Interface Board REV 5 or higher (for REV 4 or lower, use EVO-DISPREP) |
Dispenser Interface Module Cables
Model Number | Description |
---|---|
TSP-BDCBL | Bennett® 515 only cable |
TSP-GDCBL | Gilbarco™ cable |
TSP-GSDCBL | Gilbarco™ G-Site™ cable |
TSP-WDCBL | Wayne™ cable |
Internal Software Field Upgrades
Model Number | Description |
---|---|
TS-TT | Statistical Continuous Automatic Leak Detection (SCALD®) 24-hour tank testing |
TS-TRAC | Tank inventory reconciliation and autocalibration |
TS-TRAC-F | Reconciliation/autocalibration and flow rate monitoring |
TS-FLOW | Flow rate monitoring |
TS-ELLD | Electronic line leak detection |
TS-ELLD-G | Electronic line leak detection for generator applications |
TS-SCM | Secondary containment monitoring |
TS-CON | Enhanced logic conditions including value, counter, value compare, latch, and DEF/AdBlue® recirculation |
- Customers interested in SCM should see our EVO 550/5000 gauges.
- TS-CON also appropriate for DEF/AdBlue® recirculation.
EVO™ Series Upgrade Kit
Get all the Corrosion Control System capabilities of the EVO™ 600 or EVO™ 6000 on an existing EVO™ 550 or EVO™ 5000 with the easy-to-install EVO™ Series Upgrade Kit.
Model Number | Description |
---|---|
EVO-600UPG/U | Upgrade kit for EVO™ 550 to EVO™ 600, includes control module, comm port cover, and EVO 600™ jewel. No software options. |
EVO-6000UPG/U | Upgrade kit for EVO™ 5000 to EVO™ 6000, includes control module, comm port cover, and EVO 6000™ jewel. No software options. |
EVO-600UPG | Upgrade kit for EVO™ 550 to EVO™ 600, includes control module, comm port cover, and EVO 600™ jewel |
EVO-6000UPG | Upgrade kit for EVO™ 5000 to EVO™ 6000, includes control module, comm port cover, and EVO 6000™ jewel |
EVO-600UPG-W | Upgrade kit for EVO™ 550 to EVO™ 600 with Wifi, includes control module, comm port cover, Wifi hardware, and EVO 600™ jewel |
EVO-6000UPG-W | Upgrade kit for EVO™ 5000 to EVO™ 6000 with Wifi, includes control module, comm port cover, Wifi hardware, and EVO 6000™ jewel |
- Note: The serial number of the existing EVO™ must be provided when ordering the EVO-600UPG, EVO-6000UPG, EVO-600UPG-W, and EVO-6000UPG-W
EVO™ 600 and EVO™ 6000 Replacement Parts
Model Number | Description |
---|---|
EVO-6CM | Spare EVO 600/600 controller module, standard features only, no software options |
EVO-6CM/R | Replacement EVO 600/6000 controller module, factory programmed with required options |
EVO-6CM-W/R | Replacement EVO 600/6000 controller module w/ Wifi, factory programmed with required options |
TSSP-EXPPS | Expansion console power supply |
TSSP-PS | Power supply module |
TSSP-T550MB | TS-550 motherboard (for use with TS-EMS also) |
- The serial number of the old CM must be provided when ordering the EVO-6CM/R or the EVO-6CM-W/R.
Intrinsically Safe Module Spare Parts
Model Number | Description |
---|---|
FMSP-485IS | Spare/Replacement RS-485 Module |
FMSP-UDP9 | Spare/Replacement UDP Module |
TSSP-2WSNS | Spare/Replacement 2-Wire Sensor Module. |
TSSP-3WSNS | Spare/Replacement 3-Wire Sensor Module. |
TSSP-PRB | Spare/Replacement Probe Module |
TSSP-420IB | Spare/Replacement 4-20mA Module, Intrinsically Safe |
Non-Intrinsically Safe Module Spare Parts
Model Number | Description |
---|---|
TSSP-10ARLY | Spare/Replacement 10 Amp Relay Module |
TSSP-420EXP | Spare/Replacement 4-20mA Module, Explosion-Proof |
TSSP-RLY | Spare/Replacement Relay Module |
TSSP-ACI | Spare/Replacement AC Input Module |
TSSP-IO | Spare/Replacement Input/Output Module |
Spare/Replacement Hardware
Model Number | Description |
---|---|
EVO-IFBR | Spare/Replacement Interface Board for EVO™ 600/6000 |
EVO-LCD | Display upgrade for an EVO™ 600/6000 with existing Interface Board REV 5 or higher (for REV 4 or lower, use EVO-DISPREP) |
EVO-DISPREP | Display upgrade for an EVO™ 600/6000, EVO™ 550/5000 with existing Interface Board REV 4 or lower |
EVO-TMPTR | Thermal internal printer assembly upgrade for an existing EVO™ 600/6000, EVO™ 550/5000, comes with one roll of printer paper |
EVO-6CVR | Spare/Replacement Cover for EVO™ 600/6000 |
EVO-DIMIB | Internal Dispenser Interface Module upgrade for an existing EVO™ 600/ 6000, dispenser interface cable must be ordered separately |
TSSP-TRMBLK | Package of 10 assorted terminal blocks |
- Note: The serial number of the existing EVO™ must be provided when ordering the EVO-6CM-W/R.
Featured
Brochures
Title | Type | Size | |
---|---|---|---|
FFS-1040 EVO Series Complete Guide.pdf | 28.21 MB | ||
FFS-0743 EVO 600 & 6000 ATG Datasheet.pdf | 2.58 MB | ||
FFS-0941 Do More with EVO Series.pdf | 41.07 MB | ||
FFS-0779 EVO Series Upgrade Kits Brochure.pdf | 1.5 MB | ||
FFS-0846 EVO Series Flow Rate Monitoring Brochure & Ordering Guide.pdf | 9.17 MB | ||
FFS-0628 EVO Series TPI Brochure.pdf | 11.25 MB |
Catalogs
Title | Type | Size | |
---|---|---|---|
FFS-0807 (EN) Product Catalogue.pdf | 153.77 MB | ||
FFS-0367 (UL) Site Starters Ordering Guide.pdf | 64.42 MB | ||
FFS-1028 2025 UL Ordering Catalog.pdf | 95.32 MB |
Manuals
Drawings
Title | Type | Size | |
---|---|---|---|
CD_FMS_TS-EXPC_001.pdf | 0.09 MB | ||
CD_FMS_TS-EXPC_001.dwg | DWG | 0.48 MB | |
CD_FMS_EVO600_002.pdf | 0.76 MB | ||
CD_FMS_EVO600_002.dwg | DWG | 0.69 MB | |
CD_FMS_EVO6000_001.pdf | 0.83 MB | ||
CD_FMS_EVO6000_001.dwg | DWG | 0.79 MB |